International Journal for Quality in Health Care Advance Access published online on November 15, 2005
International Journal for Quality in Health Care, doi:10.1093/intqhc/mzi091
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 University Department of Anaesthesia, Glasgow Royal Infirmary, Glasgow, UK
* To whom correspondence should be addressed. Objective. To compare the view at simulated direct laryngoscopy obtained with a standard laryngoscope, with and without a disposable cover and a disposable laryngoscope blade. Design. Randomized non-blinded comparison. Setting. The high-fidelity human patient simulator at the Scottish Clinical Simulation Centre. Participants. Thirty-two anaesthetists with between 11 months and 25 years of experience. Interventions. A randomized comparison of ease of laryngoscopy with each laryngoscope option for simulated easy and difficult laryngoscopy. Main outcome measures. The best grade achievable at laryngoscopy (Cormack and Lehane grade) for each laryngoscope, for both easy and difficult laryngoscopy. Results. For the easy setting, 34% (P = 0.001) of anaesthetists graded laryngoscopy more difficult with the covered laryngoscope, and 22% (P = 0.008) with the disposable laryngoscope considered laryngoscopy more difficult than with the standard laryngoscope. For the difficult simulator setting, 69% (P < 0.001) found laryngoscopy more difficult with the covered laryngoscope and 69% (P < 0.001) with the disposable laryngoscope, when compared with the standard laryngoscope. There was no difference between the laryngoscopy grades for the covered and disposable laryngoscope for either easy (P = 0.21) or difficult (P = 0.87) simulation. Conclusions. Single-use equipment, as presently recommended for tonsillectomy surgery by the UK Department of Health, makes laryngoscopy more difficult for anaesthetists.
Accepted October 13, 2005
Article
The use of an anaesthetic simulator to assess single-use laryngoscopy equipment
Keith Anderson 1 *,
Swapna Gambhir 1,
Ronnie Glavin 2,
and
John Kinsella 1
2 Scottish Clinical Simulation Centre, Stirling Royal Infirmary, Livilands Gate, Stirling, UK
Keith Anderson, E-mail: keithanderson{at}doctors.net.uk
![]()
Abstract ![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
T. Perneger Ten reasons to conduct a randomized study in quality improvement Int. J. Qual. Health Care, December 1, 2006; 18(6): 395 - 396. [Full Text] [PDF] |
||||